Description
Refrigerated container for the transport of chilled and frozen products at a controlled temperature
- Available in versions:
o AF: temperature adjustment range: from -18°C to +10°C;
o AFH: with heating kit and temperature adjustment range: from -18°C to +40°.
- Insulation offered by container walls ensures that the temperature maintenance is guaranteed with a minimum number of ignitions of the cooling unit; this contributes limiting energy consumption.
- Cooling unit is triggered when external temperature is higher than the temperature set with the programmable digital thermostat. This allows to maintain a constant temperature even in case of very high external temperatures.
- In the AFH versions, the heating unit is triggered when external temperature is lower than the temperature set with the programmable digital thermostat. This allows to maintain a constant temperature even in case of very low external temperatures.
- Total compliance with the cold chain at all stages of transport.
- It can be transported using conventional vehicles: it allows to simultaneously transport chilled, frozen and ambient temperature products using a single non-insulated vehicle.
- Equipped with a low consumption fridge unit.
- It can be powered at 230Vac, using normal mains power.
- It can be powered at 12Vdc, depending on the model, directly or by inverter, it can be connected to the battery (or auxiliary battery) of the vehicle.
- Dual power source: during transport can be connected to the battery (or auxiliary battery) of the vehicle and, at the destination, can be connected to mains power.
- Manufactured using the rotational moulding technology: mono-block container and door (free of sharp edges, joints and welds).
- Fully recyclable at the end of the operating life.
The price is valid for 1 piece of product code K500AF. Please contact us for the price for other product codes or in case of an inquiry for several pieces
| 500 AF Versions | |
| Front opening cooling unit on top ventilated 0°C +10°C with castors | Code: K500AFTVDYM1 |
| Front opening cooling unit on back ventilated 0°C +10°C with castors | Code: K500AFDVDYM1 |
| Front opening cooling unit on top ventilated -18°C +10°C with castors | Code: K500AFTVCYM1 |
| Front opening cooling unit on back ventilated -18°C +10°C with castors | Code: K500AFDVCYM1 |
| Front opening heating cooling unit on back ventilated 0°C +40°C with castors | Code: K500AFDVDZM1 |
| Front opening heating cooling unit on top ventilated 0°C +40°C with castors | Code: K500AFTVDZM1 |
| Front opening heating cooling unit on back ventilated -18°C +40°C with castors | Code: K500AFDVCZM1 |
| Front opening heating cooling unit on top ventilated -18°C +40°C with castors | Code: K500AFTVCZM1 |
For dimensions, capacity and wieght, please see the Product sheet

